<akomaNtoso xmlns="http://docs.oasis-open.org/legaldocml/ns/akn/3.0" xmlns:finlex="http://data.finlex.fi/schema/finlex" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <act contains="originalVersion" name="main">
        <meta>
            <identification source="#organization_fi.finlex">
                <FRBRWork>
                    <FRBRthis value="/akn/fi/act/statute/2017/1010/!main"/>
                    <FRBRuri value="/akn/fi/act/statute/2017/1010"/>
                    <FRBRalias name="eli" value="http://data.finlex.fi/eli/sd/2017/1010/alkup"/>
                    <FRBRdate date="2017-12-20" name="dateIssued"/>
                    <FRBRdate date="2017-12-27" name="datePublished"/>
                    <FRBRauthor as="#role_author" href="#organization_fi.parliament"/>
                    <FRBRcountry value="fi"/>
                    <FRBRsubtype value="statute"/>
                    <FRBRnumber value="1010"/>
                    <FRBRprescriptive value="true"/>
                    <FRBRauthoritative value="true"/>
                </FRBRWork>
                <FRBRExpression>
                    <FRBRthis value="/akn/fi/act/statute/2017/1010/fin@/!main"/>
                    <FRBRuri value="/akn/fi/act/statute/2017/1010/fin@"/>
                    <FRBRalias name="eli" value="http://data.finlex.fi/eli/sd/2017/1010/alkup/fin"/>
                    <FRBRdate date="2017-12-20" name="dateIssued"/>
                    <FRBRdate date="2017-12-27" name="datePublished"/>
                    <FRBRauthor as="#role_author" href="#organization_fi.parliament"/>
                    <FRBRlanguage language="fin"/>
                </FRBRExpression>
                <FRBRManifestation>
                    <FRBRthis value="/akn/fi/act/statute/2017/1010/fin@/!main.xml"/>
                    <FRBRuri value="/akn/fi/act/statute/2017/1010/fin@.akn"/>
                    <FRBRalias name="eli" value="http://data.finlex.fi/eli/sd/2017/1010/alkup/fin/xml"/>
                    <FRBRdate date="2025-09-05" name="dateProduced"/>
                    <FRBRdate date="2017-12-27" name="datePublished"/>
                    <FRBRauthor as="#role_editor" href="#organization_fi.finlex"/>
                    <FRBRformat value="xml"/>
                </FRBRManifestation>
            </identification>
            <references source="#organization_fi.finlex">
                <TLCOrganization eId="organization_fi.finlex" href="/akn/ontology/organization/fi.finlex" showAs="Finlex"/>
                <TLCRole eId="role_author" href="/akn/ontology/role/author" showAs="Tekijä"/>
                <TLCRole eId="role_editor" href="/akn/ontology/role/editor" showAs="Toimittaja"/>
                <TLCConcept eId="decree" href="/akn/ontology/concept/statute/type-statute.decree" showAs="Asetus"/>
                <TLCConcept eId="new-statute" href="/akn/ontology/concept/statute/category-statute.new-statute" showAs="Uusi säädös"/>
            </references>
            <proprietary source="#organization_fi.finlex">
                <finlex:typeStatute refersTo="#decree"/>
                <finlex:categoryStatute refersTo="#new-statute"/>
                <finlex:documentYear>2017</finlex:documentYear>
            </proprietary>
        </meta>
        <preface>
            <p>
                <docNumber>1010/2017</docNumber>
                <docTitle>Ympäristöministeriön asetus uuden rakennuksen energiatehokkuudesta</docTitle>
            </p>
        </preface>
        <preamble>
            <formula name="enactingClause">
                <p>Ympäristöministeriön päätöksen mukaisesti säädetään maankäyttö- ja rakennuslain (132/1999) 117 g §:n 4 momentin, 131 §:n 2 momentin ja 150 f §:n 4 momentin nojalla, sellaisena kun niistä on 117 g §:n 4 momentti laissa 1151/2016, 131 §:n 2 momentti laissa 41/2014, sekä 150 f §:n 4 momentti laissa 41/2014:</p>
            </formula>
        </preamble>
        <body>
            <hcontainer finlex:outline="Säädöksen teksti" name="statuteProvisionsWrapper">
                <chapter eId="chp_1">
                    <num>1 luku</num>
                    <heading>Yleistä</heading>
                    <section eId="chp_1__sec_1">
                        <num>1 §</num>
                        <heading>Soveltamisala</heading>
                        <subsection eId="chp_1__sec_1__subsec_1">
                            <content>
                                <p>Tämä asetus koskee sisäilmaston ylläpitämiseen energiaa käyttävän, katetusta seinällisestä rakenteesta koostuvan uuden rakennuksen suunnittelua ja rakentamista. Asetus koskee myös rakennuksen laajennusta ja kerrosalaan laskettavan tilan lisäämistä. Asetus koskee kerrosalaltaan alle 50 neliömetrin kokoisen rakennuksen laajennusta vain siltä osin kuin rakennus laajennuksineen ylittää 50 neliömetriä.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_1__sec_2">
                        <num>2 §</num>
                        <heading>Määritelmät</heading>
                        <subsection eId="chp_1__sec_2__subsec_1">
                            <intro eId="chp_1__sec_2__subsec_1__intro">
                                <p>Tässä asetuksessa tarkoitetaan:</p>
                            </intro>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_1">
                                <num>1) </num>
                                <content>
                                    <p>
                                        <i>ilmanvaihdon lämmityksen tarvitsemalla lämpömäärällä </i>
                                        sitä lämpömäärää, joka tarvitaan ilmanvaihdon ilmavirran lämmittämiseksi ulkoilman lämpötilasta huonelämpötilaan;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_2">
                                <num>2) </num>
                                <content>
                                    <p>
                                        <i>ilmanvaihdon lämmitysenergian nettotarpeella</i>
                                         lämmitysenergian tarvetta, joka muodostuu ilman lämmittämisestä lämmöntalteenoton jälkeen tuloilman lämpötilaan ja mahdollisesta lämmittämisestä ennen lämmöntalteenottoa;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_3">
                                <num>3) </num>
                                <content>
                                    <p>
                                        <i>ilmanvaihdon poistoilman lämmöntalteenoton vuosihyötysuhteella</i>
                                         lämmöntalteenottolaitteistolla talteenotettavan ja hyödynnettävän lämpömäärän suhdetta ilmanvaihdon lämmityksen tarvitsemaan lämpömäärään vuodessa, kun lämmöntalteenottoa ei ole;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_4">
                                <num>4) </num>
                                <content>
                                    <p>
                                        <i>ilmanvaihtojärjestelmän ominaissähköteholla</i>
                                         (kW/(m
                                        <sup>3</sup>
                                        /s)) rakennuksen koko ilmanvaihtojärjestelmän kaikkien puhaltimien ja niihin liittyvien taajuusmuuttajien ja muiden tehonsäätölaitteiden yhteenlaskettua sähköverkosta ottamaa sähkötehoa jaettuna ilmanvaihtojärjestelmän suunnitellun käyttöajan ulospuhallusilmavirralla tai ulkoilmavirralla sen mukaisesti kumpi näistä on suurempi;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_5">
                                <num>5) </num>
                                <content>
                                    <p>
                                        <i>ilmanvaihtojärjestelmän sähköenergiankulutuksella</i>
                                         puhaltimien ja mahdollisten apulaitteiden sähkönkulutusta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_6">
                                <num>6) </num>
                                <content>
                                    <p>
                                        <i>ilmanvuotoluvulla</i>
                                         q
                                        <sub>50</sub>
                                         (m
                                        <sup>3</sup>
                                        /(h m
                                        <sup>2</sup>)) rakennuksen vaipan keskimääräistä vuotoilmavirtaa tunnissa 50 Pa:n paine-erolla rakennuksen kokonaissisämittojen mukaan laskettua rakennuksen vaipan pinta-alaa kohden;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_7">
                                <num>7) </num>
                                <content>
                                    <p>
                                        <i>jäähdytettävällä kylmällä tilalla</i>
                                         sellaista tilaa, jossa jäähdytys- ja mahdollisen lämmitysjärjestelmän avulla ympärivuotisesti ylläpidetään käyttötarkoituksen mukaista alle 17 celsiusastetta lämpötilaa;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_8">
                                <num>8) </num>
                                <content>
                                    <p>
                                        <i>jäähdytysjärjestelmän energiankulutuksella</i>
                                         jäähdytysenergian tuoton energiankulutusta ja apulaitteiden sähkönkulututusta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_9">
                                <num>9) </num>
                                <content>
                                    <p>
                                        <i>kaukolämmöllä</i>
                                         jakeluverkon kautta asiakkaana olevalle kiinteistölle toimitettua lämpöä;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_10">
                                <num>10) </num>
                                <content>
                                    <p>
                                        <i>kylmäsillalla</i>
                                         rakenteiden lujuus- tai liitossyistä johtuvaa rakennusosan pienen osan lämmönläpäisykertoimen heikentymistä;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_11">
                                <num>11) </num>
                                <content>
                                    <p>
                                        <i>lämmitetyllä nettoalalla</i>
                                         A
                                        <sub>netto</sub>
                                         (m
                                        <sup>2</sup>) lämmitettyjen kerrostasoalojen summaa kerrostasoja ympäröivien ulkoseinien sisäpintojen mukaan laskettuna;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_12">
                                <num>12) </num>
                                <content>
                                    <p>
                                        <i>lämmittämättömällä tilalla</i>
                                         sellaista tilaa, jota ei ole tarkoitettu lämmityskaudella jatkuvaan oleskeluun ja jota ei suunnitella lämmitettäväksi;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_13">
                                <num>13) </num>
                                <content>
                                    <p>
                                        <i>lämmitysenergian nettotarpeella</i>
                                         rakennuksen tilojen, ilmanvaihdon ja lämpimän käyttöveden lämmitysenergioiden yhteenlaskettua nettotarvetta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_14">
                                <num>14) </num>
                                <content>
                                    <p>
                                        <i>lämmitysjärjestelmän energiankulutuksella</i>
                                         tilojen, ilmanvaihdon ja lämpimän käyttöveden lämmityksen energiankulutusta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_15">
                                <num>15) </num>
                                <content>
                                    <p>
                                        <i>lämmönläpäisykertoimella</i>
                                         lämpövirran tiheyttä, joka jatkuvuustilassa läpäisee rakennusosan, kun lämpötilaero rakennusosan eri puolilla olevien ilmatilojen välillä on yksikön suuruinen, ja jonka tunnuksena käytetään U:ta ja yksikkönä W/(m
                                        <sup>2</sup>
                                        K);
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_16">
                                <num>16) </num>
                                <content>
                                    <p>
                                        <i>lämpimällä tilalla</i>
                                         sellaista rakennuksen tilaa, jonka huonelämpötila on +17 celsiusastetta tai korkeampi;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_17">
                                <num>17) </num>
                                <content>
                                    <p>
                                        <i>lämpimän käyttöveden lämmitysenergian nettotarpeella</i>
                                         lämmitysenergian tarvetta, joka kuluu lämpimän käyttöveden lämmittämiseen kylmän veden lämpötilasta lämpimän veden lämpötilaan;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_18">
                                <num>18) </num>
                                <content>
                                    <p>
                                        <i>massiivipuurakennuksella</i>
                                         rakennusta, jossa ulkoseinien pääasiallinen rakennusmateriaali on massiivipuurakenne, jonka keskimääräinen rakennepaksuus on vähintään 180 mm;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_19">
                                <num>19) </num>
                                <content>
                                    <p>
                                        <i>puolilämpimällä tilalla</i>
                                         sellaista tilaa, joka ei ole tarkoitettu jatkuvaan oleskeluun pelkästään normaalia sisävaatetusta käyttäen ja jonka lämpötila lämmityskaudella on keskimäärin vähintään +5 celsiusastetta mutta alle +17 celsiusastetta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_20">
                                <num>20) </num>
                                <content>
                                    <p>
                                        <i>rakennuksen laskennallisella ostoenergiankulutuksella</i>
                                         rakennuksen vakioituun käyttöön perustuvaa energiankulutusta, joka lasketaan hankittavaksi rakennukseen sähkönjakeluverkosta, kaukolämpöverkosta, kaukojäähdytysverkosta tai uusiutuvan tai fossiilisen polttoaineen sisältämänä energiana;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_21">
                                <num>21) </num>
                                <content>
                                    <p>
                                        <i>rakennuksen vaipalla</i>
                                         niitä rakennusosia, jotka erottavat lämpimän, puolilämpimän, erityisen lämpimän tai jäähdytettävän kylmän tilan ulkoilmasta, maaperästä tai lämmittämättömästä tilasta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_22">
                                <num>22) </num>
                                <content>
                                    <p>
                                        <i>rakennuksen vertailulämpöhäviöllä</i>
                                         rakennuksen vaipan, vuotoilman ja ilmanvaihdon vertailuarvoilla laskettua laskennallista lämpöhäviötä;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_23">
                                <num>23) </num>
                                <content>
                                    <p>
                                        <i>siirtokelpoisella rakennuksella</i>
                                         väliaikaiseen käyttöön tarkoitettua, liikuteltavaa rakennusta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_24">
                                <num>24) </num>
                                <content>
                                    <p>
                                        <i>suunnitteluratkaisulla</i>
                                         rakennuksen toteutettavaksi aiottua suunnitelmaa;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_25">
                                <num>25) </num>
                                <content>
                                    <p>
                                        <i>uusiutuvalla polttoaineella</i>
                                         puuta ja puupohjaista sekä muuta biopolttoainetta, ei kuitenkaan turvetta;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_26">
                                <num>26) </num>
                                <content>
                                    <p>
                                        <i>tarpeen mukaisella ilmanvaihdolla</i>
                                         järjestelmää, jolla ilmavirtoja voidaan ohjata kuormituksen tai ilman laadun mukaan käyttötilannetta vastaavasti;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_2__subsec_1__para_27">
                                <num>27) </num>
                                <content>
                                    <p>
                                        <i>ympäristössä olevasta energiasta otetulla energialla</i>
                                         rakennukseen kuuluvalla laitteistolla paikan päällä tai rakennuksen lähellä auringosta, tuulesta, maasta, ilmasta tai vedestä tuotettua lämpö- tai sähköenergiaa.
                                    </p>
                                </content>
                            </paragraph>
                        </subsection>
                    </section>
                    <section eId="chp_1__sec_3">
                        <num>3 §</num>
                        <heading>Rakennuksen energiatehokkuuden vähimmäisvaatimukset</heading>
                        <subsection eId="chp_1__sec_3__subsec_1">
                            <intro eId="chp_1__sec_3__subsec_1__intro">
                                <p>Pääsuunnittelijan, erityissuunnittelijan ja rakennussuunnittelijan on tehtäviensä mukaisesti huolehdittava uuden rakennuksen suunnittelusta siten, että se käyttötarkoituksensa mukaisesti on:</p>
                            </intro>
                            <paragraph eId="chp_1__sec_3__subsec_1__para_1">
                                <num>1) </num>
                                <content>
                                    <p>
                                        energiatehokkuudeltaan joko laskennallisen energiatehokkuuden vertailuluvun (<i>E-luvun</i>) tai rakenteellisen energiatehokkuuden mukainen;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_3__subsec_1__para_2">
                                <num>2) </num>
                                <content>
                                    <p>on rakennuksen lämpöhäviöltään vähäiselle energiantarpeelle edellytykset luova;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_1__sec_3__subsec_1__para_3">
                                <num>3) </num>
                                <content>
                                    <p>on energiatehokas laskennalliselta kesäajan huonelämpötilaltaan, energiankäytön mittaamiseltaan, lämmön ja sähkön tehon tarpeeltaan sekä käytettäessä koneellista ilmanvaihtojärjestelmää myös ilmanvaihtojärjestelmän ominaissähköteholtaan.</p>
                                </content>
                            </paragraph>
                        </subsection>
                    </section>
                </chapter>
                <chapter eId="chp_2">
                    <num>2 luku</num>
                    <heading>Energiatehokkuus</heading>
                    <section eId="chp_2__sec_4">
                        <num>4 §</num>
                        <heading>Laskennallisen energiatehokkuuden vertailuluvun vaatimustasot käyttötarkoitusluokittain</heading>
                        <subsection eId="chp_2__sec_4__subsec_1">
                            <content>
                                <p>
                                    Laskennallinen energiatehokkuuden vertailuluku (<i>E-luku</i>), jonka yksikkönä käytetään kWh
                                    <sub>E</sub>
                                    /(m
                                    <sup>2</sup>
                                     a), on energiamuotojen kertoimilla painotettu rakennuksen laskennallinen ostoenergiankulutus rakennuksen lämmitettyä nettoalaa kohden vuodessa. Rakennuksen käyttötarkoitusluokan mukaisesti laskettu E-luku ei saa ylittää seuraavia raja-arvoja:
                                </p>
                                <table>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Käyttötarkoitusluokka</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                E-luvun raja-arvokWh
                                                <sub>E</sub>
                                                /(m
                                                <sup>2</sup>
                                                 a)
                                            </p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 1) Pienet asuinrakennukset:</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p/>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                a) Erillinen pientalo ja ketjutalon osana oleva rakennus, joidenlämmitetty nettoala (A
                                                <sub>netto</sub>) on 50–150 m
                                                <sup>2</sup>
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                200–0,6 A
                                                <sub>netto</sub>
                                            </p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                b) Erillinen pientalo ja ketjutalon osana oleva rakennus, joidenlämmitetty nettoala (A
                                                <sub>netto</sub>) on enemmän kuin 150 m
                                                <sup>2</sup>
                                                 kuitenkin enintään 600 m
                                                <sup>2</sup>
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                116–0,04 A
                                                <sub>netto</sub>
                                            </p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                c) Erillinen pientalo ja ketjutalon osana oleva rakennus, joidenlämmitetty nettoala (A
                                                <sub>netto</sub>) on enemmän kuin 600 m
                                                <sup>2</sup>
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>92</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>d) Rivitalo ja asuinkerrostalo, jossa on asuinkerroksia enintään kahdessa kerroksessa</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>105</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 2) Asuinkerrostalo, jossa on asuinkerroksia vähintään kolmessa kerroksessa</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>90</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 3) Toimistorakennus, terveyskeskus</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>100</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                Luokka 4) Liikerakennus, tavaratalo, kauppakeskus,myymälärakennus lukuun ottamatta päivittäistavarakaupan alle2000 m
                                                <sup>2</sup>
                                                 yksikköä, myymälähalli, teatteri, ooppera-,konsertti- ja kongressitalo, elokuvateatteri, kirjasto, arkisto,museo, taidegalleria, näyttelyhalli
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>135</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 5) Majoitusliikerakennus, hotelli, asuntola, palvelutalo,vanhainkoti, hoitolaitos</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>160</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 6) Opetusrakennus ja päiväkoti</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>100</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 7) Liikuntahalli lukuun ottamatta uimahalliaja jäähallia</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>100</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 8) Sairaala</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>320</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                Luokka 9) Muu rakennus, varastorakennus, liikenteen rakennus,uimahalli, jäähalli, päivittäistavarakaupan alle2000 m
                                                <sup>2</sup>
                                                 yksikkö, siirtokelpoinen rakennus
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>ei raja-arvoa</p>
                                        </td>
                                    </tr>
                                </table>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_4__subsec_2">
                            <content>
                                <p>
                                    Käyttötarkoitusluokan 6 rakennuksessa, jonka lämmitetty nettoala on enintään 1 000 neliömetriä, voidaan edellä 1 momentissa esitetty E-luvun raja-arvo ylittää 5 kWh
                                    <sub>E</sub>
                                    /(m
                                    <sup>2</sup>
                                     a).
                                </p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_4__subsec_3">
                            <content>
                                <p>Massiivipuurakennuksessa voidaan edellä 1 ja 2 momentissa esitetyt E-luvun raja-arvot ylittää käyttötarkoitusluokan 1a rakennuksessa 20 prosentilla, 1b–c rakennuksessa 15 prosentilla ja muussa käyttötarkoitusluokan 1d–8 rakennuksessa 10 prosentilla.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_4__subsec_4">
                            <content>
                                <p>
                                    Käyttötarkoitusluokan 1d rakennuksessa voidaan 1 ja 3 momentissa esitetty E-luvun raja-arvo ylittää 5 kWh
                                    <sub>E</sub>
                                    /(m
                                    <sup>2</sup>
                                     a), kun rakennus on kytketty lämmitysjärjestelmään, jossa lämpö johdetaan rakennuksen ulkopuolisilla lämpöputkilla yhteisestä lämmönsiirtimestä tai lämmöntuottolaitteesta kolmeen tai useampaan rakennukseen.
                                </p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_4__subsec_5">
                            <content>
                                <p>Käyttötarkoitusluokan 9 mukaisen rakennuksen E-luku on laskettava. Laskennassa on käytettävä suunnitteluarvoja.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_4__subsec_6">
                            <intro eId="chp_2__sec_4__subsec_6__intro">
                                <p>E-luvulle asetettua raja-arvo ei sovelleta:</p>
                            </intro>
                            <paragraph eId="chp_2__sec_4__subsec_6__para_1">
                                <num>1) </num>
                                <content>
                                    <p>asunnon rakentamiseen asuinkerrostalon ullakolle;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_4__subsec_6__para_2">
                                <num>2) </num>
                                <content>
                                    <p>käyttötarkoitusluokan 1 mukaisen rakennuksen laajennukseen eikä kerrosalaan laskettavan tilan lisäämiseen;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_4__subsec_6__para_3">
                                <num>3) </num>
                                <content>
                                    <p>sellaiseen muun käyttötarkoitusluokan mukaisen rakennuksen laajennukseen tai kerrosalaan laskettavan tilan lisäämiseen, missä ilmanvaihdon tai lämmityksen järjestämisessä voi käyttää olemassa olevaa ilmanvaihto- tai lämmitysjärjestelmää;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_4__subsec_6__para_4">
                                <num>4) </num>
                                <content>
                                    <p>loma-asumiseen suunniteltavaan pientaloon.</p>
                                </content>
                            </paragraph>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_5">
                        <num>5 §</num>
                        <heading>Eri käyttötarkoitusluokkiin kuuluvat rakennuksen osat</heading>
                        <subsection eId="chp_2__sec_5__subsec_1">
                            <content>
                                <p>Rakennuksen eri käyttötarkoitusluokkiin kuuluviin osiin on sovellettava kunkin osan mukaisia E-luvun raja-arvoja. Jos rakennuksen osan lämmitetty nettoala on alle 10 prosenttia koko rakennuksen lämmitetystä nettoalasta tai rakennuksen osan lämmitetty nettoala on alle 50 neliömetriä, rakennuksen osa voidaan laskea pinta-alaltaan suurimpaan käyttötarkoitusluokkaan kuuluvaksi.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_6">
                        <num>6 §</num>
                        <heading>Rakennuksen laskennallinen ostoenergiankulutus</heading>
                        <subsection eId="chp_2__sec_6__subsec_1">
                            <content>
                                <p>Vakioituun käyttöön perustuva rakennuksen laskennallinen ostoenergiankulutus koostuu lämmitys-, ilmanvaihto- ja jäähdytysjärjestelmien sekä järjestelmien apulaitteiden, kuluttajalaitteiden ja valaistuksen energiamuodoittain eritellystä energiankulutuksesta, josta on vähennetty rakennukseen kuuluvalla laitteistolla ympäristöstä olevasta energiasta otettu energia siltä osin, kuin se on käytetty rakennuksessa siinä tapahtuvan vakioituun käyttöön perustuvan energiankulutuksen kattamiseen.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_6__subsec_2">
                            <content>
                                <p>Rakennukseen kuuluvalla laitteistolla ympäristössä olevasta energiasta otetun energian hyödyntäminen on laskettava kuukausittain tai sitä lyhyempinä ajanjaksoina.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_7">
                        <num>7 §</num>
                        <heading>E-luvun laskeminen</heading>
                        <subsection eId="chp_2__sec_7__subsec_1">
                            <intro eId="chp_2__sec_7__subsec_1__intro">
                                <p>E-luku on laskettava energiamuodoittain eritellystä rakennuksen laskennallisesta ostoenergiankulutuksesta energiamuotojen kertoimia käyttäen kaavalla:</p>
                            </intro>
                            <paragraph>
                                <content>
                                    <foreign>
                                        <finlex:latex>$  E = \frac{f_{\text{kaukolämpö}}Q_{\text{kaukolämpö}}+f_{\text{kaukojäähdytys}}Q_{\text{kaukojäähdytys}}+\sum\limits_i f_{\text{polttoaine, }i}Q_{\text{polttoaine, }i} + f_{\text{sähkö}} W_{\text{sähkö}}}{A_{\text{netto}}}  $</finlex:latex>
                                    </foreign>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_2__sec_7__subsec_2">
                            <intro eId="chp_2__sec_7__subsec_2__intro">
                                <p>jossa:</p>
                            </intro>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_1">
                                <content>
                                    <p>
                                        E on energiatehokkuuden vertailuluku, kWh
                                        <sub>E</sub>
                                        /(m
                                        <sup>2</sup>
                                         a);
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_2">
                                <content>
                                    <p>
                                        Q
                                        <sub>kaukolämpö</sub>
                                         on kaukolämmön kulutus vuodessa, kWh/a;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_3">
                                <content>
                                    <p>
                                        Q
                                        <sub>kaukojäähdytys</sub>
                                         on kaukojäähdytyksen kulutus vuodessa, kWh/a;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_4">
                                <content>
                                    <p>
                                        Q
                                        <sub>polttoaine,i</sub>
                                         on polttoaineen i sisältämän energian kulutus vuodessa, kWh/a;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_5">
                                <content>
                                    <p>
                                        W
                                        <sub>sähkö</sub>
                                         on sähkön kulutus vuodessa, missä on otettu huomioon vähennykset rakennukseen kuuluvalla laitteistolla ympäristöstä vapaasti hyödynnettävästä energiasta otetusta energiasta siltä osin, kuin se on käytetty rakennuksessa siinä tapahtuvan vakioituun käyttöön perustuvan energiankulutuksen kattamiseen, kWh/a;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_6">
                                <content>
                                    <p>
                                        f
                                        <sub>kaukolämpö</sub>
                                         on kaukolämmön energiamuodon kerroin;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_7">
                                <content>
                                    <p>
                                        f
                                        <sub>kaukojäähdytys</sub>
                                         on kaukojäähdytyksen energiamuodon kerroin;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_8">
                                <content>
                                    <p>
                                        f
                                        <sub>polttoaine,i</sub>
                                         on polttoaineen i energiamuodon kerroin;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_9">
                                <content>
                                    <p>
                                        f
                                        <sub>sähkö</sub>
                                         on sähkön energiamuodon kerroin;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_7__subsec_2__para_10">
                                <content>
                                    <p>
                                        A
                                        <sub>netto</sub>
                                         on rakennuksen lämmitetty nettoala, m².
                                    </p>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_2__sec_7__subsec_3">
                            <content>
                                <p>Energiamuotojen kertoimien lukuarvoina käytetään maankäyttö- ja rakennuslain nojalla säädettyjä lukuarvoja.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_8">
                        <num>8 §</num>
                        <heading>Vaatimukset laskentamenetelmälle</heading>
                        <subsection eId="chp_2__sec_8__subsec_1">
                            <intro eId="chp_2__sec_8__subsec_1__intro">
                                <p>Laskenta on tehtävä laskentamenetelmällä, joka ottaa huomioon vähintään seuraavat tekijät:</p>
                            </intro>
                            <paragraph eId="chp_2__sec_8__subsec_1__para_1">
                                <intro eId="chp_2__sec_8__subsec_1__para_1__intro">
                                    <p>a) rakennusosien ja niiden liitosten lämpöominaisuudet, rakennuksen ilmanpitävyys, ilmanvaihdon ilmavirta;</p>
                                </intro>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_1">
                                    <num>b)</num>
                                    <content>
                                        <p>sisäilman lämpötila;</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_2">
                                    <num>c)</num>
                                    <content>
                                        <p>lämpimän käyttöveden tarve;</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_3">
                                    <num>d)</num>
                                    <content>
                                        <p>ilmanvaihdon lämmöntalteenotto;</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_4">
                                    <num>e)</num>
                                    <content>
                                        <p>lämpökuormat henkilöistä, valaistuksesta, sähkölaitteista, lämpimästä käyttövedestä ja auringosta;</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_5">
                                    <num>f)</num>
                                    <content>
                                        <p>tilojen ja ilmanvaihdon lämmitysjärjestelmän lämpö- ja sähköenergian tarve;</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_6">
                                    <num>g)</num>
                                    <content>
                                        <p>käyttöveden lämmitysjärjestelmän lämpö- ja sähköenergian tarve;</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_7">
                                    <num>h)</num>
                                    <content>
                                        <p>ilmanvaihtojärjestelmän sähköenergiantarve;</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_2__sec_8__subsec_1__para_1__subpara_8">
                                    <num>i)</num>
                                    <content>
                                        <p>kuluttajalaitteiden ja valaistuksen sähköenergiantarve.</p>
                                    </content>
                                </subparagraph>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_2__sec_8__subsec_2">
                            <intro eId="chp_2__sec_8__subsec_2__intro">
                                <p>Ja silloin, kun rakennukseen suunnitellaan aurinkokeräin, aurinkopaneeli tai jäteveden lämmöntalteenotto:</p>
                            </intro>
                            <paragraph eId="chp_2__sec_8__subsec_2__para_1">
                                <num>j)</num>
                                <content>
                                    <p>aurinkokeräimen lämmöntuotto ja sen hyödyntäminen rakennuksessa;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_8__subsec_2__para_2">
                                <num>k)</num>
                                <content>
                                    <p>aurinkopaneelin sähköntuotto ja sen hyödyntäminen rakennuksessa;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_8__subsec_2__para_3">
                                <num>l)</num>
                                <content>
                                    <p>jäteveden lämmöntalteenotto ja sen hyödyntäminen rakennuksessa.</p>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_2__sec_8__subsec_3">
                            <content>
                                <p>Rakennuksen laskennallinen ostoenergiakulutus voidaan laskea kuukausitason laskentamenetelmällä rakennukselle, jonka sisäilman lämpötilan hallinta ei edellytä jäähdytystä tai jäähdytystä edellytetään vain tiloissa, joiden lämmitetty nettoala on alle 10 prosenttia rakennuksen lämmitetystä nettoalasta tai joiden lämmitetty nettoala on alle 50 neliömetriä.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_8__subsec_4">
                            <content>
                                <p>
                                    Jos rakennuksen sisäilman lämpötilan hallinta edellyttää jäähdytystä, rakennuksen laskennallinen ostoenergiankulutus on laskettava laskentamenetelmällä, joka 1 momentissa mainittujen tekijöiden lisäksi ottaa huomioon jäähdytysjärjestelmän lämpö- ja sähköenergiantarpeen ja jonka lämmönsiirron laskenta ottaa huomioon rakenteiden lämmönvarausominaisuuden ajasta riippuvaisena enintään tunnin aika-askeleella (<i>dynaaminen laskentamenetelmä)</i>.
                                </p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_9">
                        <num>9 §</num>
                        <heading>Säätiedot</heading>
                        <subsection eId="chp_2__sec_9__subsec_1">
                            <content>
                                <p>E-luku on laskettava liitteen 1 säävyöhykkeen I säätietojen mukaisesti.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_10">
                        <num>10 §</num>
                        <heading>Ulkoilmavirrat ja huonelämpötilat</heading>
                        <subsection eId="chp_2__sec_10__subsec_1">
                            <content>
                                <p>E-luku on laskettava käyttäen seuraavia käyttöajan ulkoilmavirtoja sekä huonelämpötilan lämmitys- ja jäähdytysrajan lämpötiloja:</p>
                                <table>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Käyttötarkoitusluokka</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Ulkoilmavirta</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Lämmitysraja</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Jäähdytysraja</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p> </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                dm
                                                <sup>3</sup>
                                                /(s m
                                                <sup>2</sup>)
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>°C</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>°C</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 1)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0,4</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>21</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>27</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 2)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0,5</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>21</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>27</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 3)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>2</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>21</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>25</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 4)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>2</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>18</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>25</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 5)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>2</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>21</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>25</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 6)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>3</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>21</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>25</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 7)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>2</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>18</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>25</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 8)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>4</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>22</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>25</p>
                                        </td>
                                    </tr>
                                </table>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_10__subsec_2">
                            <content>
                                <p>Poistoilmavirrat on laskettava ulkoilmavirtaa vastaavilla arvoilla.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_10__subsec_3">
                            <content>
                                <p>
                                    Muun kuin käyttötarkoitusluokan 1 ja 2 rakennuksen ilmanvaihdon ulkoilmavirtana on käytettävä laskennassa käyttöajan ulkopuolella vähintään 0,15 dm
                                    <sup>3</sup>
                                    /s neliömetrille.
                                </p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_10__subsec_4">
                            <content>
                                <p>
                                    Käyttötarkoitusluokan 2 rakennuksessa, jossa asukkaalla on mahdollisuus ohjata tulo- ja poistoilmavirtoja siten, että niitä voidaan huoneistokohtaisesti tehostaa vähintään 30 prosenttia ja pienentää vähintään 40 prosenttia suunnitellun käyttöajan ilmavirroista, rakennuksen ulkoilmavirtana voidaan käyttää 0,4 dm
                                    <sup>3</sup>
                                    /s neliömetrille.
                                </p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_10__subsec_5">
                            <content>
                                <p>
                                    Tarpeenmukaisella ilmanvaihdolla varustetussa rakennuksen tilassa, mitä ohjataan läsnäoloon tai olosuhdemittaukseen perustuvalla rakennusautomaatiojärjestelmällä, voidaan käyttää 20 prosenttia pienempää ulkoilmavirran arvoa tai ilmanvaihtosuunnitelmaan perustuen määrittää tarpeenmukaisen ilmanvaihdon suhteellinen vaikutus 1 momentissa esitettyyn ulkoilmavirran arvoon. Ilmanvaihtosuunnitelmaan perustuvassa tarkastelussa voidaan tilan ilmanvaihtoa laskennassa pienentää kuitenkin enintään arvoon 0,35 dm
                                    <sup>3</sup>
                                    /s neliömetrille rakennuksen käyttöaikana. Koko rakennuksen ulkoilmavirran arvoa voidaan laskennallisesti pienentää tarpeenmukaisen ilmanvaihdon vaikutusta vastaavalla osuudella ottaen huomioon tarpeenmukaisen ilmanvaihdon kattaman rakennuksen osan suhde koko rakennuksen pinta-alaan.
                                </p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_11">
                        <num>11 §</num>
                        <heading>Rakennuksen vakioitu käyttö</heading>
                        <subsection eId="chp_2__sec_11__subsec_1">
                            <content>
                                <p>E-luvun laskennassa käytettävä rakennuksen vuorokautinen ja viikoittainen käyttöaika, keskimääräinen valaistuksen, kuluttajalaitteiden ja ihmisten läsnäolon käyttöaste rakennuksen käyttöajan aikana sekä sisäiset lämpökuormat lämmitettyä nettoalaa kohti ovat seuraavat:</p>
                                <table>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Käyttötarkoitusluokka</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Kellonaika</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Käyttöaika </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Käyttöaste</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Sisäinen lämpökuormalämmitettyä nettoalaa kohti</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p/>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p/>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Vuorokautinenh/24h</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Viikoittainend/7d</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>-</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                ValaistusW/m
                                                <sup>2</sup>
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                Kuluttaja-laitteetW/m
                                                <sup>2</sup>
                                            </p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                IhmisetW/m
                                                <sup>2</sup>
                                            </p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 1)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>00:00-24:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>24</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>7</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>valaistus 0,1muut 0,6</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>6</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>3</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>2</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 2</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>00:00-24:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>24</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>7</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>valaistus 0,1muut 0,6</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>9</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>4</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>3</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 3)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>07:00-18:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>11</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>5</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0,65</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>10</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>12</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>5</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 4)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>08:00-21:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>13</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>6</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>1</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>19</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>1</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>2</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 5)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>00:00-24:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>24</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>7</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0,3</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>11</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>4</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>4</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 6)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>08:00-16:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>8</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>5</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0,6</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>14</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>8</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>14</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 7)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>08:00-22:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>14</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>7</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0,5</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>10</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>5</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 8)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>00:00-24:00</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>24</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>7</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>0,6</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>7</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>9</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>8</p>
                                        </td>
                                    </tr>
                                </table>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_11__subsec_2">
                            <intro eId="chp_2__sec_11__subsec_2__intro">
                                <p>Valaistuksen, kuluttajalaitteiden ja ihmisten aiheuttama vuotuinen lämpökuorma Q (kWh/m2) on laskettava kaavalla:</p>
                            </intro>
                            <paragraph>
                                <content>
                                    <foreign>
                                        <finlex:latex>$  Q = kP \frac{\tau_d}{24}\frac{\tau_w}{7}\frac{8760}{1000}  $</finlex:latex>
                                    </foreign>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_2__sec_11__subsec_3">
                            <intro eId="chp_2__sec_11__subsec_3__intro">
                                <p>jossa:</p>
                            </intro>
                            <paragraph eId="chp_2__sec_11__subsec_3__para_1">
                                <content>
                                    <p>k on keskimääräinen valaistuksen ja kuluttajalaitteiden käyttöaste sekä ihmisten läsnäolo rakennuksen käyttöajan aikana;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_11__subsec_3__para_2">
                                <content>
                                    <p>
                                        P on lämpökuorma W/m
                                        <sup>2</sup>;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_11__subsec_3__para_3">
                                <content>
                                    <p>
                                        τ
                                        <sub>d</sub>
                                         on rakennuksen käyttötuntien lukumäärä vuorokaudessa h;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_11__subsec_3__para_4">
                                <content>
                                    <p>
                                        τ
                                        <sub>w</sub>
                                         on rakennuksen käyttöpäivien lukumäärä viikossa d.
                                    </p>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_2__sec_11__subsec_4">
                            <content>
                                <p>Valaistuksen, kuluttajalaitteiden ja ihmisten aiheuttama kuukausittainen lämpökuorma on määritettävä vuotuisesta lämpökuormasta kuukauden päivien lukumäärän perusteella.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_11__subsec_5">
                            <content>
                                <p>Edellä 1 momentissa säädetyn sijasta valaistuksen lämpökuorman arvona voidaan käyttää valaistussuunnitelman mukaista arvoa, jos valaistussuunnitelmasta voidaan lämpökuorma määrittää tilatyyppikohtaisesti valaistuksen tehotiheyden ja valaistuksen ohjauksen perusteella. Rakennuksen keskimääräinen valaistuksen lämpökuorma lasketaan tilatyyppien pinta-aloilla painotettuna keskiarvona.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_11__subsec_6">
                            <content>
                                <p>Ilmanvaihtojärjestelmän käyntiaika on laskettava siten, että 1 momentin mukaiseen käyttöaikaan lisätään tunti ennen käyttöajan alkua ja tunti käyttöajan päättymisen jälkeen. Lisäystä ei tehdä jatkuvasti käytettäviin rakennuksiin.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_12">
                        <num>12 §</num>
                        <heading>Lämpimän käyttöveden vakioitu käyttö</heading>
                        <subsection eId="chp_2__sec_12__subsec_1">
                            <content>
                                <p>Lämpimän käyttöveden vakioidun käytön lämmitysenergian nettotarpeena on käytettävä seuraavia käyttötarkoitusluokittaisia lämmitysenergian nettotarpeita rakennuksen lämmitettyä nettoalaa kohden:</p>
                                <table>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Käyttötarkoitusluokka</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>
                                                Lämpimän käyttöveden lämmitysenergian nettotarve vuodessakWh/(m
                                                <sup>2</sup>
                                                 a)
                                            </p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p> </p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 1)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>35</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 2)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>35</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 3)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>6</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 4)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>4</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 5)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>40</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 6)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>11</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 7)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>20</p>
                                        </td>
                                    </tr>
                                    <tr>
                                        <td class="colsep-1 rowsep-1">
                                            <p>Luokka 8)</p>
                                        </td>
                                        <td class="colsep-1 rowsep-1">
                                            <p>30</p>
                                        </td>
                                    </tr>
                                </table>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_12__subsec_2">
                            <content>
                                <p>Luokassa 1 on lämpimän käyttöveden lämmitysenergian nettotarve kuitenkin enintään 4 200 kWh vuodessa asuntoa kohden.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_12__subsec_3">
                            <content>
                                <p>Lämpimän käyttöveden lämmitysenergian nettotarpeena voi laskennassa käyttää 15 prosenttia edellä mainittuja pienempiä arvoja, jos rakennuksen käyttövesiverkosto varustetaan vakiopaineventtiilillä tai muulla vastaavalla painetasoa säätävällä tekniikalla.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_13">
                        <num>13 §</num>
                        <heading>Laskentavyöhykkeet</heading>
                        <subsection eId="chp_2__sec_13__subsec_1">
                            <content>
                                <p>Yhden käyttötarkoituksen rakennuksen E-luvun laskennassa voidaan koko rakennus laskea yhtenä laskentavyöhykkeenä. Useita eri käyttötarkoituksia sisältävän rakennuksen E-luvun laskennassa rakennus on jaettava käyttötarkoitusta ja käyttöaikoja vastaaviin laskentavyöhykkeisiin.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_14">
                        <num>14 §</num>
                        <heading>Erikoistilat ja eräät tekniset järjestelmät</heading>
                        <subsection eId="chp_2__sec_14__subsec_1">
                            <content>
                                <p>Rakennuksessa olevan ravintolan, ammattikeittiön, ruokalan, kahvilan, laboratorion tai muuna erikoistilan E-luvun laskenta on tehtävä näiden osalta rakennuksen tai rakennuksen osan käyttötarkoitusta vastaavilla lähtöarvoilla.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_14__subsec_2">
                            <content>
                                <p>E-luvun laskennassa ei oteta huomioon tässä asetuksessa erittelemättömiä teknisiä järjestelmiä.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_15">
                        <num>15 §</num>
                        <heading>Lämmitysenergian nettotarve</heading>
                        <subsection eId="chp_2__sec_15__subsec_1">
                            <content>
                                <p>Rakennuksen tilojen lämmitysenergian nettotarve on laskettava johtumislämpöhäviöistä, vuotoilman lämpöhäviöistä, korvausilman ja tuloilman lämpenemisestä tilassa huonelämpötilaan, joista on vähennettävä auringon ja sisäisten lämpökuormien vaikutus. Rakennukseen tulevan aurinkoenergian laskennassa on otettava huomioon rakennuksessa olevat auringonsuojausratkaisut.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_15__subsec_2">
                            <content>
                                <p>Ilmanvaihdon lämmitysenergian nettotarve on laskettava ilman lämmittämisestä lämmöntalteenoton jälkeen tuloilman lämpötilaan ja mahdollisesta lämmittämisestä ennen lämmöntalteenottoa.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_15__subsec_3">
                            <content>
                                <p>Lämpimän käyttöveden lämmitysenergian nettotarve on laskettava 12 §:n mukaan.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_16">
                        <num>16 §</num>
                        <heading>Lämpöhäviön huomioon ottaminen E-luvun laskennassa</heading>
                        <subsection eId="chp_2__sec_16__subsec_1">
                            <content>
                                <p>E-lukua laskettaessa rakennuksen vaipan lämpöhäviö on laskettava rakennuksen vaipan sisämitoilla. Laskennassa on otettava huomioon rakenteiden ja niiden liitosten kylmäsillat. Rakennuksen vaipan yksittäisiä kylmäsiltoja ei oteta huomioon.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_16__subsec_2">
                            <content>
                                <p>Lämpöhäviön laskennassa on otettava huomioon maaperän ja ryömintätilan vaikutus lämpöhäviöön.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_17">
                        <num>17 §</num>
                        <heading>Vuotoilmavirran huomioon ottaminen E-luvun laskennassa</heading>
                        <subsection eId="chp_2__sec_17__subsec_1">
                            <intro eId="chp_2__sec_17__subsec_1__intro">
                                <p>
                                    E-lukua laskettaessa on käytettävä rakennuksen vaipan ilmanvuotolukuna suunnitteluarvoa, jos ilmanpitävyys osoitetaan teollisen talonrakennuksen laadunvarmistusmenettelyllä tai tullaan osoittamaan mittaamalla. Muutoin laskennassa on käytettävä rakennuksen vaipan ilmanvuotolukuna arvoa 4 m
                                    <sup>3</sup>
                                    /(h m
                                    <sup>2</sup>). Vuotoilmavirta q
                                    <sub>v,vuotoilma</sub>
                                     on laskettava kaavalla:
                                </p>
                            </intro>
                            <paragraph>
                                <content>
                                    <foreign>
                                        <finlex:latex>$  q_{v,\text{ vuotoilma}} = \frac{q_{50}}{3600 \cdot x} A_{\text{vaippa}}  $</finlex:latex>
                                    </foreign>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_2__sec_17__subsec_2">
                            <intro eId="chp_2__sec_17__subsec_2__intro">
                                <p>jossa:</p>
                            </intro>
                            <paragraph eId="chp_2__sec_17__subsec_2__para_1">
                                <content>
                                    <p>
                                        q
                                        <sub>v,vuotoilma</sub>
                                         on vuotoilmavirta, m³/s;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_17__subsec_2__para_2">
                                <content>
                                    <p>
                                        q
                                        <sub>50</sub>
                                         on rakennusvaipan ilmanvuotoluku, m
                                        <sup>3</sup>
                                        /(h·m
                                        <sup>2</sup>);
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_17__subsec_2__para_3">
                                <content>
                                    <p>
                                        A
                                        <sub>vaippa</sub>
                                         on rakennusvaipan pinta-ala, m
                                        <sup>2</sup>;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_17__subsec_2__para_4">
                                <content>
                                    <p>x on kerroin, joka on yksikerroksisille rakennuksille 35, kaksikerroksisille 24, kolmi- ja nelikerroksisille 20 ja näitä korkeammille rakennuksille 15;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_2__sec_17__subsec_2__para_5">
                                <content>
                                    <p>
                                        3600 on kerroin, joka muuttaa ilmavirran yksiköstä m
                                        <sup>3</sup>
                                        /h yksikköön m
                                        <sup>3</sup>
                                        /s.
                                    </p>
                                </content>
                            </paragraph>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_18">
                        <num>18 §</num>
                        <heading>Lämmitysjärjestelmän energiankäyttö</heading>
                        <subsection eId="chp_2__sec_18__subsec_1">
                            <content>
                                <p>Rakennuksen lämmitysjärjestelmän energiankäyttöön kuuluvat tilojen lämmityksen, ilmanvaihdon lämmityksen ja lämpimän käyttöveden valmistuksen energiankäyttö.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_18__subsec_2">
                            <content>
                                <p>Lämmitysjärjestelmän energiankulutuksen laskennassa otetaan huomioon lämmönjaon häviöt rakennuksen sisä- ja ulkopuolella, lämmön luovutuksen häviöt, lämmitysenergian tuoton häviöt ja muunnokset, lämpimän käyttöveden siirron ja kiertojohdon häviöt rakennuksen sisä- ja ulkopuolella, varastoinnin häviöt sekä lämmitysjärjestelmän apulaitteiden sähkönkulutus.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_18__subsec_3">
                            <content>
                                <p>Jos rakennus on kytketty lämmitysjärjestelmään, jossa lämpö johdetaan rakennuksen ulkopuolisilla lämpöputkilla yhteisestä lämmönsiirtimestä tai lämmöntuottolaitteesta useampaan rakennukseen, on kyseisten lämpöputkien lämpöhäviö jaettava rakennusten kesken pinta-alojen suhteessa.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_18__subsec_4">
                            <content>
                                <p>Jos käyttötarkoitusluokan 2 mukaisen rakennuksen asuinhuoneissa on vesikiertoinen lämmitys ja märkätiloissa sähköinen lattialämmitys, asuinhuoneiston tilojen lämmitysenergian nettotarpeesta voidaan laskea kohdistuvan 35 prosenttia märkätilojen lattialämmitykselle ja 65 prosenttia asuinhuoneiden lämmitysjärjestelmälle ellei märkätilojen sähköisen lattialämmityksen osuutta tilojen nettotarpeesta lasketa tarkemmin dynaamisella laskentatyökalulla ottaen huomioon suunnitellut ilmavirrat ja tilojen väliset siirtoilmavirtaukset. Märkätilojen sisälämpötilana on käytettävä 22 celsiusastetta. Märkätilojen sähköisen lattialämmityksen osuus asuinhuoneiston tilojen lämmitysenergian nettotarpeesta on kuitenkin enintään suunnitelmassa esitetyn sähköisen lattialämmityksen asennustehon ja 8760 tunnin käyttöajan perusteella laskettu osuus.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_18__subsec_5">
                            <content>
                                <p>Jos lämpimän käyttöveden kiertojohto sijaitsee rakennuksen vaipan eristeen ulkopuolella, ei lämpimän käyttöveden kierron lasketusta lämpöhäviöstä aiheudu rakennuksen tiloihin lämpökuormaa. Jos kiertojohto sijaitsee rakennuksen vaipan eristeessä, on rakennuksen tilojen lämpökuormaan lisättävä 25 prosenttia lämpimän käyttöveden kierron lasketusta lämpöhäviöstä. Jos kiertojohto sijaitsee rakennuksen vaipan sisäpuolella, on rakennuksen tilojen lämpökuormaan lisättävä 50 prosenttia lämpimän käyttöveden kierron lasketusta lämpöhäviöstä. Jos lämpimän käyttöveden varaaja sijaitsee rakennuksen vaipan sisäpuolella, on rakennuksen tilojen lämpökuormaan lisättävä 50 prosenttia varaajan lasketusta lämpöhäviöstä.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_18__subsec_6">
                            <content>
                                <p>Lämmitysjärjestelmän mahdollisista lämpötilarajoituksista ja osatehomitoituksesta johtuva lisälämmitysenergia on laskettava mukaan lämmitysjärjestelmän energiankäyttöön.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_19">
                        <num>19 §</num>
                        <heading>Tulisija ja ilmalämpöpumppu</heading>
                        <subsection eId="chp_2__sec_19__subsec_1">
                            <content>
                                <p>Varaavan tulisijan asuinhuoneistoon tuottamaksi lämmitysenergiaksi voidaan laskea enintään 3 000 kilowattituntia vuodessa tulisijaa kohden.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_2__sec_19__subsec_2">
                            <content>
                                <p>Ilma-ilmalämpöpumpun asuinhuoneistoon tuottamaksi lämmitysenergiaksi voidaan laskea enintään 3 000 kilowattituntia vuodessa laitetta kohden, ellei laitteen toimintaa rakennuksessa lasketa tarkemmin dynaamisella laskentamenetelmällä huomioon ottaen tilojen väliset ilmavirtaukset ja lämpötilaerot.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_20">
                        <num>20 §</num>
                        <heading>Ilmanvaihtojärjestelmä</heading>
                        <subsection eId="chp_2__sec_20__subsec_1">
                            <content>
                                <p>Rakennuksen ilmanvaihtojärjestelmän ilmavirrat ja käyntiajat on laskettava 10 ja 11 §:n mukaisesti. Koneellisen ilmanvaihtojärjestelmän sähköenergiankulutus on laskettava ilmavirtojen, ominaissähkötehojen ja käyntiaikojen avulla kaikille rakennuksessa oleville ilmanvaihtokoneille ja huippuimureille.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_21">
                        <num>21 §</num>
                        <heading>Jäähdytysjärjestelmä</heading>
                        <subsection eId="chp_2__sec_21__subsec_1">
                            <content>
                                <p>Rakennuksen jäähdytysjärjestelmän energiankulutusta laskettaessa on otettava huomioon jäähdytysenergian tuoton energiankulutus ja apulaitteiden sähköenergiankulutus siltä osin kuin sisälämpötilan hallinta edellyttää järjestelmien käyttöä.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_2__sec_22">
                        <num>22 §</num>
                        <heading>Valaistuksen ja kuluttajalaitteiden sähkönkäyttö</heading>
                        <subsection eId="chp_2__sec_22__subsec_1">
                            <content>
                                <p>Rakennuksessa käytettävän valaistuksen ja kuluttajalaitteiden vuotuinen sähköenergian kulutus on laskettava 11 §:n mukaisesti niiden lämpökuormasta. Valaistuksen ja kuluttajalaitteiden sähköenergian kulutus on samansuuruinen kuin niiden lämpökuorma.</p>
                            </content>
                        </subsection>
                    </section>
                </chapter>
                <chapter eId="chp_3">
                    <num>3 luku</num>
                    <heading>Rakennuksen lämpöhäviö</heading>
                    <section eId="chp_3__sec_23">
                        <num>23 §</num>
                        <heading>Rakennuksen lämpöhäviön määrittäminen</heading>
                        <subsection eId="chp_3__sec_23__subsec_1">
                            <content>
                                <p>Rakennuksen lämpöhäviö on rakennuksen vaipan, vuotoilman ja ilmanvaihdon yhteenlaskettu lämpöhäviö. Rakennuksen lämpöhäviö voi olla enintään yhtä suuri kuin vertailuarvoilla rakennukselle määritetty vertailulämpöhäviö. Rakennuksen lämpöhäviölle asetettu vaatimus koskee erikseen rakennuksen lämpimiä ja puolilämpimiä tiloja.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_23__subsec_2">
                            <content>
                                <p>Sellaista rakennuksen laajennusta tai kerrosalaan laskettavan tilan lisäämistä, missä ilmanvaihdon ja lämmityksen järjestämisessä voi käyttää olemassa olevaa ilmanvaihto- tai lämmitysjärjestelmää, koskevat rakennuksen lämpöhäviön osalta vain rakennuksen vaipan lämpöhäviölle asetetut vaatimukset. Loma-asumiseen suunniteltavaa pientaloa, joka on tarkoitettu käytettäväksi vuodessa vähintään neljä kuukautta, koskevat rakennuksen lämpöhäviön osalta vain rakennuksen vaipan lämpöhäviölle asetetut vaatimukset. Rakennuksen lämpöhäviötä koskeva vaatimus ei koske ennen heinäkuun 1 päivää 2012 valmistetuista osista koottua siirtokelpoista rakennusta, jota käytetään edelleen samaan käyttötarkoitukseen.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_3__sec_24">
                        <num>24 §</num>
                        <heading>Rakennuksen vaipan lämpöhäviö</heading>
                        <subsection eId="chp_3__sec_24__subsec_1">
                            <intro eId="chp_3__sec_24__subsec_1__intro">
                                <p>Rakennuksen vaipan lämpöhäviö on laskettava eri rakennusosien pinta-alojen ja lämmönläpäisykertoimien perusteella kaavalla:</p>
                            </intro>
                            <paragraph>
                                <content>
                                    <foreign>
                                        <finlex:latex>$  \begin{align*}
        \sum H_{\text{joht}} &amp;= \sum (U_{\text{ulkoseinä}} A_{\text{ulkoseinä}}) + \sum (U_{\text{yläpohja}} A_{\text{yläpohja}}) \\
        &amp;+ \sum (U_{\text{alapohja}} A_{\text{alapohja}}) + \sum (U_{\text{ikkuna}} A_{\text{ikkuna}}) + \sum (U_{\text{ovi}} A_{\text{ovi}})
    \end{align*}  $</finlex:latex>
                                    </foreign>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_3__sec_24__subsec_2">
                            <intro eId="chp_3__sec_24__subsec_2__intro">
                                <p>jossa:</p>
                            </intro>
                            <paragraph eId="chp_3__sec_24__subsec_2__para_1">
                                <content>
                                    <p>
                                        ∑H
                                        <sub>joht</sub>
                                         on rakennuksen vaipan lämpöhäviö, W/K;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_24__subsec_2__para_2">
                                <content>
                                    <p>U on rakennusosan lämmönläpäisykerroin, W/(m²K);</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_24__subsec_2__para_3">
                                <content>
                                    <p>A on rakennusosan pinta-ala, m².</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_24__subsec_2__para_4">
                                <intro eId="chp_3__sec_24__subsec_2__para_4__intro">
                                    <p>Lämpimän tai jäähdytettävän kylmän tilan rakennuksen vaipan lämpöhäviön vertailuarvo on laskettava käyttämällä rakennusosien lämmönläpäisykertoimina seuraavia vertailuarvoja:</p>
                                </intro>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_1">
                                    <num>a)</num>
                                    <content>
                                        <p>
                                            seinä 	0,17 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_2">
                                    <num>b)</num>
                                    <content>
                                        <p>massiivipuuseinä, jonka keskimääräinen</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_3">
                                    <content>
                                        <p>
                                            paksuus on vähintään 180 mm 	0,40 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_4">
                                    <num>c)</num>
                                    <content>
                                        <p>
                                            yläpohja ja ulkoilmaan rajoittuva alapohja 	0,09 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_5">
                                    <num>d)</num>
                                    <content>
                                        <p>
                                            ryömintätilaan rajoittuva alapohja 	0,17 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_6">
                                    <num>e)</num>
                                    <content>
                                        <p>
                                            maata vasten oleva rakennusosa 	0,16 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_7">
                                    <num>f)</num>
                                    <content>
                                        <p>ikkuna, kattoikkuna, ovi, kattovalokupu,</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_4__subpara_8">
                                    <content>
                                        <p>
                                            savunpoisto- ja uloskäyntiluukku 	1,0 W/(m
                                            <sup>2</sup>
                                             K).
                                        </p>
                                    </content>
                                </subparagraph>
                            </paragraph>
                            <paragraph eId="chp_3__sec_24__subsec_2__para_5">
                                <intro eId="chp_3__sec_24__subsec_2__para_5__intro">
                                    <p>Siirtokelpoisen rakennuksen sekä puolilämpimän tilan rakennuksen vaipan lämpöhäviön vertailuarvo on laskettava käyttämällä rakennusosien lämmönläpäisykertoimina seuraavia vertailuarvoja:</p>
                                </intro>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_1">
                                    <num>a)</num>
                                    <content>
                                        <p>
                                            seinä 	0,26 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_2">
                                    <num>b)</num>
                                    <content>
                                        <p>massiivipuuseinä, jonka rakenteen</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_3">
                                    <content>
                                        <p>
                                            keskimääräinen paksuus vähintään 180 mm 	0,60 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_4">
                                    <num>c)</num>
                                    <content>
                                        <p>
                                            yläpohja ja ulkoilmaan rajoittuva alapohja 	0,14 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_5">
                                    <num>d)</num>
                                    <content>
                                        <p>
                                            ryömintätilaan rajoittuva alapohja 	0,26 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_6">
                                    <num>e)</num>
                                    <content>
                                        <p>
                                            maata vasten oleva rakennusosa 	0,24 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_7">
                                    <num>f)</num>
                                    <content>
                                        <p>ikkuna, kattoikkuna, ovi, kattovalokupu,</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_5__subpara_8">
                                    <content>
                                        <p>
                                            savunpoisto- ja uloskäyntiluukku 	1,4 W/(m
                                            <sup>2</sup>
                                             K).
                                        </p>
                                    </content>
                                </subparagraph>
                            </paragraph>
                            <paragraph eId="chp_3__sec_24__subsec_2__para_6">
                                <intro eId="chp_3__sec_24__subsec_2__para_6__intro">
                                    <p>Loma-asumiseen suunniteltavan pientalon, joka on tarkoitettu käytettäväksi vähintään neljä kuukautta vuodessa, rakennuksen vaipan lämpöhäviön vertailuarvo on laskettava käyttämällä rakennusosien lämmönläpäisykertoimina seuraavia vertailuarvoja:</p>
                                </intro>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_1">
                                    <num>a)</num>
                                    <content>
                                        <p>
                                            seinä 	0,24 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_2">
                                    <num>b)</num>
                                    <content>
                                        <p>massiivipuuseinä, jonka rakenteen</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_3">
                                    <content>
                                        <p>
                                            keskimääräinen paksuus vähintään 130 mm 	0,80 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_4">
                                    <num>c)</num>
                                    <content>
                                        <p>
                                            yläpohja ja ulkoilmaan rajoittuva alapohja 	0,15 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_5">
                                    <num>d)</num>
                                    <content>
                                        <p>
                                            ryömintätilaan rajoittuva alapohja 	0,19 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_6">
                                    <num>e)</num>
                                    <content>
                                        <p>
                                            maata vasten oleva rakennusosa 	0,24 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_7">
                                    <num>f)</num>
                                    <content>
                                        <p>ikkuna, kattoikkuna, ovi, kattovalokupu,</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_3__sec_24__subsec_2__para_6__subpara_8">
                                    <content>
                                        <p>
                                            savunpoisto- ja uloskäyntiluukku 	1,4 W/(m
                                            <sup>2</sup>
                                             K).
                                        </p>
                                    </content>
                                </subparagraph>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_3__sec_24__subsec_3">
                            <content>
                                <p>Rakennuksen yhteenlasketun ikkunapinta-alan vertailuarvo on 15 prosenttia rakennuksen kokonaan tai osittain maanpäällisten kerrosten kerrostasoalojen yhteismäärästä, mutta kuitenkin enintään 50 prosenttia rakennuksen julkisivupinta-alasta. Ikkunan pinta-ala on laskettava ikkunan kehän ulkomittojen mukaan.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_24__subsec_4">
                            <content>
                                <p>Laskennassa on käytettävä suunnitellun rakennuksen koko- ja geometriatietoja. Rakennuksen vaipan eri rakennusosien pinta-alat on määritettävä rakennuksen kokonaissisämittojen mukaan.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_24__subsec_5">
                            <content>
                                <p>Rakennuksen suunnitteluratkaisun vaipan lämpöhäviön laskennassa on käytettävä suunniteltuja rakennusosakohtaisia lämmönläpäisykertoimia ja ikkunapinta-aloja.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_3__sec_25">
                        <num>25 §</num>
                        <heading>Rakennuksen vuotoilman lämpöhäviön laskeminen</heading>
                        <subsection eId="chp_3__sec_25__subsec_1">
                            <intro eId="chp_3__sec_25__subsec_1__intro">
                                <p>Rakennuksen vuotoilman lämpöhäviö on laskettava kaavalla:</p>
                            </intro>
                            <paragraph>
                                <content>
                                    <foreign>
                                        <finlex:latex>$  H_{\text{vuotoilma}} = \rho_i c_{pi} q_{v,\text{vuotoilma}}  $</finlex:latex>
                                    </foreign>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_3__sec_25__subsec_2">
                            <intro eId="chp_3__sec_25__subsec_2__intro">
                                <p>jossa:</p>
                            </intro>
                            <paragraph eId="chp_3__sec_25__subsec_2__para_1">
                                <content>
                                    <p>
                                        H
                                        <sub>vuotoilma</sub>
                                         on vuotoilman lämpöhäviö, W/K;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_25__subsec_2__para_2">
                                <content>
                                    <p>
                                        ρ
                                        <sub>i</sub>
                                         on ilman tiheys, 1,2 kg/m³;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_25__subsec_2__para_3">
                                <content>
                                    <p>
                                        c
                                        <sub>pi</sub>
                                         on ilman ominaislämpökapasiteetti, 1000 Ws/(kg K);
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_25__subsec_2__para_4">
                                <content>
                                    <p>
                                        q
                                        <sub>v,vuotoilma</sub>
                                         on vuotoilmavirta, m³/s.
                                    </p>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_3__sec_25__subsec_3">
                            <content>
                                <p>
                                    Vuotoilmavirta q
                                    <sub>v,vuotoilma</sub>
                                     on määritettävä 17 §:n mukaisesti. Rakennuksen vertailulämpöhäviötä laskettaessa rakennuksen vaipan ilmanvuotoluvun vertailuarvona on käytettävä arvoa 2,0 m
                                    <sup>3</sup>
                                    /(h m
                                    <sup>2</sup>).
                                </p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_25__subsec_4">
                            <content>
                                <p>
                                    Rakennuksen suunnitteluratkaisun lämpöhäviötä laskettaessa on käytettävä suunnitteluarvoa rakennuksen vaipan ilmanvuotoluvun arvona. Jos ilmanpitävyyden suunnitteluarvon toteutumista ei osoiteta mittaamalla tai teollisen talonrakennuksen laadunvarmistusmenettelyllä, on käytettävä rakennuksen vaipan ilmanvuotoluvun arvoa 4,0 m
                                    <sup>3</sup>
                                    /(h m
                                    <sup>2</sup>).
                                </p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_3__sec_26">
                        <num>26 §</num>
                        <heading>Rakennuksen ilmanvaihdon lämpöhäviön laskeminen</heading>
                        <subsection eId="chp_3__sec_26__subsec_1">
                            <intro eId="chp_3__sec_26__subsec_1__intro">
                                <p>Rakennuksen ilmanvaihdon lämpöhäviö on laskettava kaavalla:</p>
                            </intro>
                            <paragraph>
                                <content>
                                    <foreign>
                                        <finlex:latex>$  H_{iv} = \rho_i c_{pi} q_{v,\text{poisto}} t_d t_V (1 - \eta_\alpha)  $</finlex:latex>
                                    </foreign>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_3__sec_26__subsec_2">
                            <intro eId="chp_3__sec_26__subsec_2__intro">
                                <p>jossa:</p>
                            </intro>
                            <paragraph eId="chp_3__sec_26__subsec_2__para_1">
                                <content>
                                    <p>
                                        H
                                        <sub>iv</sub>
                                         on ilmanvaihdon ominaislämpöhäviö, W/K;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_26__subsec_2__para_2">
                                <content>
                                    <p>
                                        ρ
                                        <sub>i</sub>
                                         on ilman tiheys, 1,2 kg/m³;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_26__subsec_2__para_3">
                                <content>
                                    <p>
                                        c
                                        <sub>pi</sub>
                                         on ilman ominaislämpökapasiteetti, 1000 Ws/(kg K);
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_26__subsec_2__para_4">
                                <content>
                                    <p>
                                        q
                                        <sub>v, poisto</sub>
                                         on vakioidun käytön mukainen laskennallinen poistoilmavirta, m³/s;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_26__subsec_2__para_5">
                                <content>
                                    <p>
                                        t
                                        <sub>d</sub>
                                         on ilmanvaihtojärjestelmän keskimääräinen vuorokautinen käyntiaikasuhde, h/24h;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_26__subsec_2__para_6">
                                <content>
                                    <p>
                                        t
                                        <sub>v</sub>
                                         on ilmanvaihtojärjestelmän viikoittainen käyntiaikasuhde, vrk/7 vrk;
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_3__sec_26__subsec_2__para_7">
                                <content>
                                    <p>
                                        η
                                        <sub>a</sub>
                                         on ilmanvaihdon poistoilman lämmöntalteenoton vuosihyötysuhde.
                                    </p>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_3__sec_26__subsec_3">
                            <content>
                                <p>Ilmanvaihdon vertailulämpöhäviön ja suunnitteluratkaisun ilmanvaihdon lämpöhäviön laskennassa on käytettävä samoja ilmavirtojen arvoja ja käyntiaikoja.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_26__subsec_4">
                            <content>
                                <p>Ilmanvaihdon ilmavirta on laskettava 10 §:n mukaisesti. Laskettaessa vertailulämpöhäviötä ja suunnitteluratkaisun lämpöhäviötä ei tarpeenmukaista ilmanvaihtoa oteta huomioon. Ilmanvaihdon käyntiaika on laskettava lisäämällä yksi tunti ennen ja yksi tunti jälkeen 11 §:n mukaiseen rakennuksen käyttöaikaan. Lisäystä ei tehdä jatkuvasti käytettäviin rakennuksiin. Käyttötarkoitusluokan 9 rakennuksille on käytettävä rakennuksen suunnitteluarvoja ilmavirtoina ja ilmanvaihdon käyntiaikana.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_26__subsec_5">
                            <content>
                                <p>Vertailulämpöhäviön laskennassa on käytettävä rakennuksen ilmanvaihtojärjestelmän ilmanvaihdon poistoilman lämmöntalteenoton vuosihyötysuhteena arvoa 55 prosenttia. Rakennuksen vertailulämpöhäviön laskennassa yksittäisen tilan poistoilman lämmöntalteenoton vuosihyötysuhteen arvo on nolla prosenttia, jos poistoilman likaisuus estää lämmöntalteenoton toiminnan, tilan lämpötila lämmityskaudella on alle +10 celsiusastetta eikä poistoilmasta ole saatavissa lämpöä talteen kustannustehokkaasti tai jos ilmanvaihtojärjestelmän toiminta perustuu pääasiassa korkeus- ja lämpötilaerojen sekä tuulen aiheuttamiin paine-eroihin.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_26__subsec_6">
                            <content>
                                <p>Jos käytetään koneellista ilmanvaihtoa, ilmanvaihtokoneen poistoilman lämmöntalteenoton vuosihyötysuhde on määritettävä käyttäen lämmöntalteenottolaitteen ominaisuuksia ja ilmanvaihtokoneen suunniteltuja ilmavirtoja sekä liitteessä 1 säädetyn säävyöhykkeen I säätietoja.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_3__sec_26__subsec_7">
                            <content>
                                <p>Kahden tai useamman ilmanvaihtokoneen poistoilman lämmöntalteenoton vuosihyötysuhde on määritettävä suunniteltujen ilmavirtojen ja käyntiaikojen painotettuna vuosihyötysuhteena. Rakennuksen suunnitteluratkaisun ilmanvaihdon lämpöhäviö on laskettava käyttäen näin määritettyä poistoilman lämmöntalteenoton vuosihyötysuhdetta ja 3 momentin mukaisia ilmavirtojen arvoja ja käyntiaikoja.</p>
                            </content>
                        </subsection>
                    </section>
                </chapter>
                <chapter eId="chp_4">
                    <num>4 luku</num>
                    <heading>Erinäiset säännökset</heading>
                    <section eId="chp_4__sec_27">
                        <num>27 §</num>
                        <heading>Rakennuksen ilmanpitävyys</heading>
                        <subsection eId="chp_4__sec_27__subsec_1">
                            <content>
                                <p>
                                    Rakennuksen vaipan ilmanvuotoluku (q
                                    <sub>50</sub>) voi olla enintään 4,0 m
                                    <sup>3</sup>
                                    /(h m
                                    <sup>2</sup>). Ilmanvuotoluku voi ylittää arvon 4,0 m
                                    <sup>3</sup>
                                    /(h m
                                    <sup>2</sup>), jos rakennuksen käytön vaatimat rakenteelliset ratkaisut sitä edellyttävät.
                                </p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_4__sec_28">
                        <num>28 §</num>
                        <heading>Routaeristys, perusmuurin lämmöneristys ja eräiden tilojen välinen eristys</heading>
                        <subsection eId="chp_4__sec_28__subsec_1">
                            <content>
                                <p>Rakennuksen alapohjan lämmöneristyksen suunnittelussa on otettava huomioon routaeristys ja mahdollinen rakennuksen vaippaan kuulumaton perusmuurin lämmöneristys routavaurioiden välttämiseksi.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_4__sec_28__subsec_2">
                            <content>
                                <p>
                                    Jäähdytettävän kylmän tilan ja muiden tilojen välisen seinän ja välipohjan lämmönläpäisykerroin saa olla enintään 0,27 W/(m
                                    <sup>2</sup>
                                     K) ja oven enintään 1,4 W/(m
                                    <sup>2</sup>
                                     K).
                                </p>
                            </content>
                        </subsection>
                        <subsection eId="chp_4__sec_28__subsec_3">
                            <content>
                                <p>
                                    Lämpimän tilan ja puolilämpimän tilan välisen seinän ja välipohjan lämmönläpäisykerroin saa olla enintään 0,60 W/(m
                                    <sup>2</sup>
                                     K) ja ikkunan ja oven enintään 2,8 W/(m
                                    <sup>2</sup>
                                     K) lukuun ottamatta loma-asumiseen suunniteltavaa pientaloa.
                                </p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_4__sec_29">
                        <num>29 §</num>
                        <heading>Laskennallinen kesäajan huonelämpötila</heading>
                        <subsection eId="chp_4__sec_29__subsec_1">
                            <content>
                                <p>Laskennallinen kesäajan huonelämpötila ei saa ylittää jäähdytysrajan arvoa 27 celsius-astetta käyttötarkoitusluokassa 2 ja jäähdytysrajan arvoa 25  celsiusastetta käyttötarkoitusluokissa 3–8 enemmän kuin 150 astetuntia kesäkuun 1 päivän ja elokuun 31 päivän välisenä aikana suunnitteluratkaisun mukaista ilmavirtaa käyttäen. Kesäajan huonelämpötilan vaatimuksenmukaisuus on osoitettava eri tilatyyppien lämpötilalaskennalla. Laskennassa on käytettävä ilmavirtaa lukuun ottamatta E-luvun laskennan mukaisia lähtötietoja. Kesäajan huonelämpötilaa koskevaa vaatimusta ei sovelleta käyttötarkoitusluokkaan 1 ja 9 kuuluviin rakennuksiin. Kesäajan huonelämpötilan laskennassa on käytettävä dynaamista laskentatyökalua.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_4__sec_30">
                        <num>30 §</num>
                        <heading>Rakennuksen koneellisen ilmanvaihtojärjestelmän ominaissähköteho</heading>
                        <subsection eId="chp_4__sec_30__subsec_1">
                            <content>
                                <p>
                                    Jos rakennuksessa on koneellinen ilmanvaihtojärjestelmä, voi koneellisen tulo- ja poistoilmajärjestelmän ominaissähköteho olla enintään 1,8 kW/(m
                                    <sup>3</sup>
                                    /s) ja koneellisen poistoilmajärjestelmän ominaissähköteho enintään 0,9 kW/(m
                                    <sup>3</sup>
                                    /s).
                                </p>
                            </content>
                        </subsection>
                        <subsection eId="chp_4__sec_30__subsec_2">
                            <content>
                                <p>Ilmanvaihtojärjestelmän ominaissähköteho voi ylittää edellä mainitut arvot rakennuksen käyttötarkoituksen mukaisen sisäilmaston niin edellyttäessä.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_4__sec_31">
                        <num>31 §</num>
                        <heading>Energiankäytön mittaus rakennuksessa</heading>
                        <subsection eId="chp_4__sec_31__subsec_1">
                            <content>
                                <p>Rakennuksessa on oltava energiankäytön mittauksen mahdollistavat mittauslaitteet tai mittausvalmius, jotta rakennuksen energiankäyttöä voidaan seurata tärkeimpien kulutuskohteiden ja rakennuksen koko kulutuksen osalta tai tällainen seurantamahdollisuus on oltava helposti toteutettavissa.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_4__sec_32">
                        <num>32 §</num>
                        <heading>Rakennuksen lämmön ja sähkön tehon tarve</heading>
                        <subsection eId="chp_4__sec_32__subsec_1">
                            <content>
                                <p>Rakennuksen lämmitysjärjestelmän lämmitysteho on mitoitettava siten, että rakennuksen tilojen suunnitellut lämpöolot ja ilmanvaihto voidaan ylläpitää rakennuksen sijaintipaikkakunnan mukaisen säävyöhykkeen mitoittavilla ulkolämpötiloilla, jotka esitetään liitteessä 1.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_4__sec_32__subsec_2">
                            <content>
                                <p>Suunnittelussa on otettava huomioon mahdollisuuksia sähkön huipputehon tarpeen pienentämiseksi ja sähkötehon ohjattavuuden parantamiseksi.</p>
                            </content>
                        </subsection>
                    </section>
                    <section eId="chp_4__sec_33">
                        <num>33 §</num>
                        <heading>Rakenteellinen energiatehokkuus</heading>
                        <subsection eId="chp_4__sec_33__subsec_1">
                            <content>
                                <p>Rakennuksen energiatehokkuudelle 4 §:ssä asetettujen vaatimusten täyttyminen voidaan 4 §:stä poiketen osoittaa rakenteellisella energiatehokkuudella.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_4__sec_33__subsec_2">
                            <intro eId="chp_4__sec_33__subsec_2__intro">
                                <p>Käyttötarkoitusluokkiin 1 ja 2 kuuluva rakennus täyttää energiatehokkuudelle asetetut vaatimukset, jos:</p>
                            </intro>
                            <paragraph eId="chp_4__sec_33__subsec_2__para_1">
                                <num>1)</num>
                                <intro eId="chp_4__sec_33__subsec_2__para_1__intro">
                                    <p>rakennuksen lämpöhäviö on enintään yhtä suuri kuin rakenteellisen energiatehokkuuden vertailuarvoilla rakennukselle määritetty vertailulämpöhäviö vastaavasti laskettuna kuin 24, 25 ja 26 §:ssä on esitetty. Rakennusosien lämmönläpäisykertoimien, ilmanvuotoluvun ja poistoilman lämmöntalteenoton vuosihyötysuhteen vertailuarvot ovat:</p>
                                </intro>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_1">
                                    <num>a)</num>
                                    <content>
                                        <p>
                                            seinä, käyttötarkoitusluokka 1 	0,12 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_2">
                                    <num>b)</num>
                                    <content>
                                        <p>
                                            seinä, käyttötarkoitusluokka 2 	0,14 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_3">
                                    <num>c)</num>
                                    <content>
                                        <p>
                                            yläpohja ja ulkoilmaan rajoittuva alapohja 	0,07 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_4">
                                    <num>d)</num>
                                    <content>
                                        <p>ryömintätilaan rajoittuva tuuletettu alapohja ja maata vasten</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_5">
                                    <content>
                                        <p>
                                            oleva rakennusosa
	0,10 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_6">
                                    <num>e)</num>
                                    <content>
                                        <p>ikkuna, kattoikkuna, ovi, kattovalokupu,</p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_7">
                                    <content>
                                        <p>
                                            savunpoisto- ja uloskäyntiluukku 	0,70 W/(m
                                            <sup>2</sup>
                                             K);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_8">
                                    <num>f)</num>
                                    <content>
                                        <p>
                                            rakennuksen ilmanvuotoluku (q
                                            <sub>50</sub>) 	0,60 m
                                            <sup>3</sup>
                                            /(h m
                                            <sup>2</sup>);
                                        </p>
                                    </content>
                                </subparagraph>
                                <subparagraph eId="chp_4__sec_33__subsec_2__para_1__subpara_9">
                                    <num>g)</num>
                                    <content>
                                        <p>poistoilman lämmöntalteenoton vuosihyötysuhde 65 prosenttia;</p>
                                    </content>
                                </subparagraph>
                            </paragraph>
                            <paragraph eId="chp_4__sec_33__subsec_2__para_2">
                                <num>2) </num>
                                <content>
                                    <p>
                                        Rakennus on varustettu koneellisella tulo- ja poistoilmanvaihtojärjestelmällä, jonka ominaissähköteho on enintään 	1,5 kW/(m
                                        <sup>3</sup>
                                        /s);
                                    </p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_4__sec_33__subsec_2__para_3">
                                <num>3) </num>
                                <content>
                                    <p>Rakennuksen lämmitysjärjestelmänä on käytettävä kaukolämpöä, maalämpöpumppua tai ilma-vesilämpöpumppua.</p>
                                </content>
                            </paragraph>
                        </subsection>
                    </section>
                    <section eId="chp_4__sec_34">
                        <num>34 §</num>
                        <heading>Energiaselvitys</heading>
                        <subsection eId="chp_4__sec_34__subsec_1">
                            <intro eId="chp_4__sec_34__subsec_1__intro">
                                <p>Rakennusta suunniteltaessa on laadittava energiaselvitys. Energiaselvitys sisältää tarkastelut:</p>
                            </intro>
                            <paragraph eId="chp_4__sec_34__subsec_1__para_1">
                                <num>a)</num>
                                <content>
                                    <p>E-luku 4 §:n mukaan ja E-luvun laskennan keskeiset lähtötiedot ja tulokset, rakennuksen lämpöhäviön määräystenmukaisuus 23 §:n mukaan ja koneellisen ilmanvaihtojärjestelmän ominaissähköteho 30 §:n mukaan; tai</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_4__sec_34__subsec_1__para_2">
                                <num>b)</num>
                                <content>
                                    <p>rakenteellisen energiatehokkuuden määräystenmukaisuus 33 §:n mukaan.</p>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_4__sec_34__subsec_2">
                            <intro eId="chp_4__sec_34__subsec_2__intro">
                                <p>Lisäksi energiaselvitys sisältää tarkastelut:</p>
                            </intro>
                            <paragraph eId="chp_4__sec_34__subsec_2__para_1">
                                <num>a)</num>
                                <content>
                                    <p>laskennallinen kesäaikainen huonelämpötila 29 §:n mukaan;</p>
                                </content>
                            </paragraph>
                            <paragraph eId="chp_4__sec_34__subsec_2__para_2">
                                <num>b)</num>
                                <content>
                                    <p>rakennuksen energiatodistus, jos rakennuksen energiatodistusta koskeva lainsäädäntö sitä edellyttää.</p>
                                </content>
                            </paragraph>
                        </subsection>
                        <subsection eId="chp_4__sec_34__subsec_3">
                            <content>
                                <p>Energiaselvitys on päivitettävä ennen rakennuksen käyttöönottoa, jos lupavaiheen energiaselvityksen perusteena oleviin suunnitelmiin on tullut muutoksia. Rakennusvaiheen vastuuhenkilön on tehtävä merkintä rakennustyön tarkastusasiakirjaan siitä, että rakennustyö vastaa energiaselvityksessä esitettyä.</p>
                            </content>
                        </subsection>
                    </section>
                </chapter>
                <chapter eId="chp_5">
                    <num>5 luku</num>
                    <heading>Voimaantulo ja siirtymäsäännökset</heading>
                    <section eId="chp_5__sec_35">
                        <num>35 §</num>
                        <heading>Voimaantulo</heading>
                        <subsection eId="chp_5__sec_35__subsec_1">
                            <content>
                                <p>Tämä asetus tulee voimaan 1 päivänä tammikuuta 2018.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_5__sec_35__subsec_2">
                            <content>
                                <p>Tällä asetuksella kumotaan ympäristöministeriön asetus rakennusten energiatehokkuudesta 2/11.</p>
                            </content>
                        </subsection>
                        <subsection eId="chp_5__sec_35__subsec_3">
                            <content>
                                <p>Tämän asetuksen voimaan tullessa vireillä olevaan hankkeeseen sovelletaan tämän asetuksen voimaan tullessa voimassa olleita säännöksiä.</p>
                            </content>
                        </subsection>
                    </section>
                </chapter>
            </hcontainer>
            <hcontainer finlex:outline="Esityöt ja allekirjoitukset" name="conclusions">
                <hcontainer finlex:outline="Esityöt" name="preliminaryWork">
                    <content>
                        <p>Euroopan parlamentin ja neuvoston direktiivi 2015/1535/EU (32015L1535); EUVL L 241, 17.9.2015, s. 1</p>
                        <p>Euroopan parlamentin ja neuvoston direktiivi 2012/27/EU (32012L0027); EUVL L 315, 14.11.2012, s. 1</p>
                        <p>Euroopan parlamentin ja neuvoston direktiivi 2010/31/EU (32010L0031); EUVL L 153, 18.6.2010, s. 13</p>
                        <p>Euroopan parlamentin ja neuvoston direktiivi 2009/28/EY (32009L0028); EUVL L 140, 5.6.2009, s. 16</p>
                    </content>
                </hcontainer>
                <hcontainer finlex:outline="Allekirjoitukset" name="signatures">
                    <content>
                        <p>Helsingissä 20 päivänä joulukuuta 2017</p>
                        <p>
                            <signature>
                                <role refersTo="">Asunto-, energia- ja ympäristöministeri</role>
                                <person refersTo="">Kimmo Tiilikainen</person>
                            </signature>
                            <signature>
                                <role refersTo="">Rakennusneuvos</role>
                                <person refersTo="">Pekka Kalliomäki</person>
                            </signature>
                        </p>
                    </content>
                </hcontainer>
            </hcontainer>
            <hcontainer name="attachments">
                <hcontainer name="attachment">
                    <content>
                        <p>
                            <a href="media/6800.pdf">Liite 1: YM:a uuden rakennuksen energiatehokkuudesta</a>
                        </p>
                    </content>
                </hcontainer>
            </hcontainer>
        </body>
    </act>
</akomaNtoso>